OVHcloud Network Status

Current status
Legend
  • Operational
  • Degraded performance
  • Partial Outage
  • Major Outage
  • Under maintenance
bhs2-21ab-n56
Incident Report for Network & Infrastructure
Resolved
The switch rebooted today at 15h00 EST (21h00 FR)

Reason: Reset triggered due to HA policy of Reset
System version: 7.0(5)N1(1a)
Service: ptplc hap reset

We plan to update this switch in priority.

Update(s):

Date: 2016-10-25 00:42:59 UTC
Some ports was in vpc error, everything has been fixed. The services is back to normal.

Date: 2016-10-24 23:48:32 UTC
The bhs2-21b-n56 just rebooted.

Date: 2016-10-24 23:48:19 UTC
The server is back to normal

Date: 2016-10-24 23:47:54 UTC
117768 Eth116/1/9 up failed Compatibility check failed -
117776 Eth116/1/17 up failed Compatibility check failed -
117778 Eth116/1/19 up failed Compatibility check failed -
117788 Eth116/1/29 up failed Compatibility check failed -
117791 Eth116/1/32 up failed Compatibility check failed -
117793 Eth116/1/34 up failed Compatibility check failed -
117798 Eth116/1/39 up failed Compatibility check failed -

A lot of port have consistency issue between the 2 switchs.

bhs2-21a-n56# sh vpc consistency-parameters interface Eth116/1/19

Legend:
Type 1 : vPC will be suspended in case of mismatch

Name Type Local Value Peer Value
------------- ---- ---------------------- -----------------------
Speed 1 1000 Mb/s 10 Mb/s
Duplex 1 full full
Port Mode 1 trunk trunk
Native Vlan 1 6 6
MTU 1 1500 1500
Admin port mode 1 pvlan trunk sec pvlan trunk sec
Shut Lan 1 No No
vPC card type 1 Empty Empty
Allowed VLANs - 117,316 117,316
Local suspended VLANs - 117,316 -

We will shut/no shut the failed port.


Date: 2016-10-24 23:43:02 UTC
Some servers are unstable on A side but seem fine on B side.
Posted Oct 24, 2016 - 23:42 UTC