We have a problem with the card 9 of Nexus 7010 that manage the infrastructure pCC
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet9/5 is down (Link failure)
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-4-IF_NON_QUALIFIED_TRANSCEIVER: Non-qualified transceiver on interface Ethernet9/1 was detected
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-4-IF_NON_QUALIFIED_TRANSCEIVER: Non-qualified transceiver on interface Ethernet9/2 was detected
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-4-IF_NON_QUALIFIED_TRANSCEIVER: Non-qualified transceiver on interface Ethernet9/3 was detected
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-4-IF_NON_QUALIFIED_TRANSCEIVER: Non-qualified transceiver on interface Ethernet9/4 was detected
2012 Feb 2 17:24:55 pcc-1a-n7 %ETHPORT-4-IF_NON_QUALIFIED_TRANSCEIVER: Non-qualified transceiver on interface Ethernet9/5 was detected
2012 Feb 2 17:44:10 pcc-1a-n7 %M2FIB-SLOT8-2-M2FIB_MAC_TBL_PRGMING: Failed to program the mac table. MAC Table is Full for this entry
2012 Feb 2 19:47:33 pcc-1a-n7 %DIAG_PORT_LB-2-PORTLOOPBACK_TEST_FAIL: Module:9 Test:PortLoopback failed 10 consecutive times. Faulty module
: affected ports:6-32 Error:Error in Forwarding Asic FWD DE Block
We will proceed to the change of the card. No interruption of the trafic is predicted.
Update(s):
Date: 2012-02-06 17:31:03 UTC Performed.
Ports are up :
Eth9/1 pcc-21-n5:e1/17 connected trunk full 10G 10Gbase-(un
Eth9/2 pcc-23-n5:e1/17 connected trunk full 10G 10Gbase-(un
Eth9/3 pcc-25-n5:e1/17 connected trunk full 10G 10Gbase-(un
Eth9/4 pcc-27-n5:e1/17 connected trunk full 10G 10Gbase-(un
Eth9/5 pcc-29-n5:e1/17 connected trunk full 10G 10Gbase-(un