FS#6571 — rbx-97 - 10/04
Scheduled Maintenance Report for Network & Infrastructure
Completed
We upgrade tonight the supervision cards on this switch and then we do a software update. This will allow up to insert new F2 cards in the router.
Beginning of the workings at 00:00 CEST.

Update(s):

Date: 2012-04-11 06:31:58 UTC
Switch is in a stable status.

Date: 2012-04-11 01:42:33 UTC
We are reassembling links to rbx-97 one by one in order not to impact the routing.




Date: 2012-04-11 01:41:40 UTC
We have noticed a traffic loss to Roubaix3 and 4 especially on networks routed by vss-5a/b and vss-3. These routers have had an increase of load due to changes in QSPF caused by reassembled links on rbx-97.



Date: 2012-04-11 01:36:57 UTC
Routing to the RPS filers and NAS cloud was interrupted for about 3 minutes.



Date: 2012-04-10 23:56:29 UTC
All cards are updated. We are replacing the F1 cards by F2 ones.



Date: 2012-04-10 23:55:40 UTC
The sups are updated. The upgrade of linecards is processing.

Date: 2012-04-10 23:54:58 UTC
The system switched to 8G:

rbx-97-n7# sh system resources
Load average: 1 minute: 0.41 5 minutes: 0.75 15 minutes: 1.04
Processes : 592 total, 2 running
CPU states : 12.5% user, 16.0% kernel, 71.5% idle
Memory usage: 8260944K total, 2094892K used, 6166052K free
Current memory status: OK

We are launching the upgrade software.

Date: 2012-04-10 23:53:57 UTC
The sup inactive is upgraded. We have forced the switchover and upgraded the other sup which is booting.

Date: 2012-04-10 23:52:42 UTC
We are starting works. We are upgrading the RAM on the sup inactive card.
Posted Apr 10, 2012 - 17:06 UTC